Short answer: No. 30W per port is a port ceiling, not the unit budget.
| Model | PoE ports | Per port | Total budget | Max consumption | Input |
| IDS3008F4-8P | Ports 1-8 | 30W | 240W | 255W incl. PoE / 15W excl. | 44-57VDC |
| IDS3008F4-U/T | Ports 1-4 or 1-8 | 60W / 90W | 240 / 360 / 480 / 720W | 250 / 370 / 490 / 730W | 44-57VDC |
Short answer: IDS3008F4-U/T and IDS5008F4-U/T — same power tiers, different temperature rating and uplinks.
| Item | IDS3008F4-U/T | IDS5008F4-U/T |
| Uplinks | 4 x 1G SFP | 4 x 10G SFP+ |
| Operating temperature | -10 ~ +60°C ⚠ | -40 ~ +75°C ✔ |
| PoE | 802.3af/at/bt, 60W (Type-3) or 90W (Type-4), ports 1-4 or 1-8 | |
| Budget tiers | 240 / 360 / 480 / 720W | |
| Backplane / input | 24 Gbps / 44-57VDC | |
The 802.3bt pin assignment differs from 802.3at: V- on pins 1, 2, 7, 8 and V+ on pins 3, 4, 5, 6 (four pairs).
Short answer: Most models -40°C to +75°C (storage -40°C to +85°C); the 802.3bt model IDS3008F4-U/T is the exception at -10°C to +60°C.
Operating temperature is the powered range, storage temperature the unpowered range — state them on separate lines in specifications. IDS1616F2-16P is specified with -40~+75°C storage rather than +85°C. See the DIN-rail industrial switch range for the full catalog.
Short answer: 1G SFP through 10G SFP+, 2-8 uplink ports depending on model.
Two SFP slots do not guarantee compatibility: the transceiver must match fiber type, wavelength, connector and distance of the remote device.
Short answer: Unmanaged suits small static networks; managed (L2+/L3) is required for VLANs, redundancy, diagnostics and multi-service isolation.
The IDS1808F2-8P L2+ documents 802.1Q VLAN (4K, MAC/IP-based), 802.1p QoS with 8 queues, IGMP/MLD snooping, LACP trunking (4 groups x 4 ports), 512-entry ACL, storm control, port mirroring, rate limiting, 802.1X, SNMP/SSH/Telnet/Console/Web and ring recovery under 20 ms. The Layer 3 IDS3008F4-8P adds 24 Gbps switching, 23.8 Mpps forwarding, 4.1 Mbit buffer, 8K MAC, 16K jumbo frames and 32 L3 interfaces.
Short answer: Surge protection for power and data ports is stated without a kV figure — request the quantified level. The IPE90-bt injector is rated 6kV (10/700µs, IEC 61000-4-5).
For external protection, Hinet offers DIN-rail protectors IPV101-6KV, IPV101-10KV, IPV201-6KV and IPV201-10KV (100M/1000M optional). The complete arrangement must include power supplies, cable routing, bonding and grounding.
Short answer: IPE15/30/60/90-bt injectors (15-90W, 802.3af/at/bt), IPS15/30/60 splitters, IDX101/201/102/202/104/204 extenders.
IPE90-bt: 90W single port, 44-57VDC in / 48VDC out, -40~+75°C, IP40, 6kV surge, 103x78x32mm. Note: IP40 — outdoor deployment still needs enclosure protection. More power accessories are listed under DIN-rail industrial power supply.
Short answer: Datasheet; PoE budget table (voltage x temperature x tier); high-temperature derating curve; quantified surge kV level; IEC 60529 IP report; EN 61373 evidence for rail use; IEEE 802.3bt consistency report for bt models; written warranty terms.
Warranty tiers are 1/2/5 years; external power supplies and wireless antennas are covered for three months; packaging, cords, cables, software and documentation are excluded. See the warranty and service policy.
| Model | Ports | PoE / port | Budget | Temp | Uplinks |
| IDS3008F4-8P | 8 x Gb RJ45 | 30W | 240W | -40~+75°C | 4 x 1G SFP |
| IDS3008F4-U/T | 8 x Gb RJ45 | 60W/90W | 240-720W | -10~+60°C | 4 x 1G SFP |
| IDS5008F4-U/T | 8 x Gb RJ45 | 60W/90W | 240-720W | -40~+75°C | 4 x 10G SFP+ |
| IDS1808F2-8P | 8 x Gb RJ45 | 30W | — | -40~+75°C | 2 x 1G SFP |
| IDS1616F2-16P | 16 x Gb RJ45 | 30W | — | -40~+75°C | 2 x 1G SFP |
| IDS1708T2-8P | 8 x Gb RJ45 | 30W | — | -40~+75°C | 2 x 10G SFP+ |
Phone
0755-23706700
Email
[email protected]
Address
201-202, Building 6, Zhonggang Plaza, Fuhai Subdistrict, Bao'an District, Shenzhen
Hinet Industrial