Short answer: The first digit is the solid particle ingress level, the second the water level. IP40 blocks objects ≥1mm with zero water protection; IP67 is dust-tight with 1m/30min immersion; IP30 blocks objects ≥2.5mm with zero water protection.
| Code | Solids | Water | Meaning |
| IP30 | 3 | 0 | Blocks ≥2.5mm objects; no water protection |
| IP40 | 4 | 0 | Blocks ≥1.0mm objects; no water protection |
| IP67 | 6 | 7 | Dust tight; short immersion ≤1m / 30min |
Hinet verified models by level: IP30 — IDS3008F4-8P (Layer 3, 240W budget); IP40 — IS1008-8P-M12, IS1608-8P-M12, IS1808F2-8P-M12, TNS1008-8P, IDS1808F2-8P, IDS1616F2-16P, IPE90-bt; IP67 — the IWS1005/1008/1605/1608/1808/3008-8P-M12 series.
Procurement one-liner: if rain can reach the device, only IP67 qualifies. IP30 and IP40 are identical in water protection — none.
Short answer: No. EN50155 and IP ingress protection are independent requirements.
The Hinet EN50155 industrial switch range contains both IP40 and IP67 models. Choose by installation: IP40 inside sealed vehicles or cabinets; IP67 for trackside, tunnel entrances, exposed poles and mining. Request the IEC 60529 test report — a metal housing description alone proves nothing.
Short answer: IP40 provides no water protection. A rain cover only works if the whole enclosure system is sealed and rated.
| Installation | Minimum level |
| Indoor control cabinet | IP30 / IP40 fine |
| Sealed outdoor enclosure | IP30 / IP40 acceptable with glands and caps |
| Simple rain shelter / open bracket | IP67 required |
| Trackside / pole / tunnel mouth | IP67 required |
| Mine / heavy dust + water | IP67 required |
| Underwater long-term | None — IP67 is short immersion only |
Short answer: Not always — but where rain reaches the device, IP40 has no substitute.
IP67 costs more, validates longer, and sealed housings worsen heat dissipation — high-temperature PoE derating becomes the likely bottleneck (no derating curves are published). For indoor cabinets, IP40 is sufficient and economical. Within the same Hinet series, the IP67 and IP40 counterparts keep the same M12 coding and speed class: IWS1008-8P-M12 and IS1008-8P-M12 are both 8 x 100M M12 D-code 30W; IWS1608-8P-M12 and IS1608-8P-M12 are both Gigabit M12 X-code.
Short answer: Required PoE = sum of device power + 20-25% headroom. IP rating interacts with thermal derating: sealed enclosures run hotter and PoE output can fall below nameplate.
Example: 8 cameras x 15W = 120W → 150W with margin. IDS3008F4-8P publishes 240W total budget (30W/port, ports 1-8, 255W max including PoE, 44-57VDC) — ample for the load, but it is IP30 and needs a sealed outdoor enclosure or an IP67 alternative. IWS1808-8P-M12 and IWS1608-8P-M12 are IP67 with 30W per port but do not publish whole-unit budgets.
Short answer: "Surge protection" without a kV figure is not a specification. Request the quantified level and design the full protection chain.
Hinet pages state power/data port surge protection with EMS items EN61000-4-2/-4-3/-4-4/-4-5/-4-6 but no kV value. Quantified data exists: IPE90-bt = 10/700µs 6kV (IEC 61000-4-5); rail-mounted protectors IPV101-6KV, IPV201-6KV, IPV101-10KV, IPV201-10KV. IP rating and surge protection address different hazards — outdoor projects need both, plus bonding and grounding design.
Short answer: No. IP rating is a system property — housing, connectors, cables, sealing rings and assembly must all qualify.
The full Hinet M12 accessory line is rated IP67 (M12-P-5-A-IP67-1, M12-R-8-X-IP67-1, M12-M-8-X-IP67-1, M12-R-4-D-IP67-1, DH24-F-LC-IP67-1 and more). Coding must match: D-code for 100M models (IS1008-8P-M12, TNS1008-8P), X-code for Gigabit (IS1608-8P-M12, IWS1608-8P-M12). Unused ports must use metal caps (M12-CAP-F-M / M12-CAP-M-M) for IP67 sealing — plastic caps (M12-CAP-*-P) only block dust. DIY connectors: metal variants (M12-CON-4-D-IP67-M etc.) are required for IP67.
Short answer: Six items, with the IEC 60529 test report at the core.
| Level | Models | Temp | Notes |
| IP30 | IDS3008F4-8P | -40~+75°C | Layer 3, 240W PoE budget |
| IP40 | IS1008-8P-M12, IS1608-8P-M12, IS1808F2-8P-M12, TNS1008-8P, IDS1808F2-8P, IDS1616F2-16P, IPE90-bt | -40~+75°C | Enclosure required when wet |
| IP67 | IWS1005/1008/1605/1608/1808/3008-8P-M12 | -40~+75°C | Direct rain exposure OK |
| Pending verification | IS3008G4BP/E4BP, IS3012/3016/3020 G4BP series | -40~+75°C | Confirm with supplier before approval |